2-6

WebPak 3000 OIM User Guide

2.2.1 Drive Status Indicators

The indicators on the right of the display allow you to check the status of the drive. In
figure 2.2, the Interlocks OK and Drive Ready indicators are shown on. The indicators
are described in table 2.3.

Table 2.3 – Drive Status Indicators

Indicator

State

Description

Fault

On

At least one fault has occurred. See chapter 7 for fault information.

Off

There are no faults.

Alarm

On

At least one alarm has occurred. See chapter 7 for alarm information.

Off

There are no alarms.

Interlocks OK

On

The coast/DB contact and all customer interlocks (Regulator board terminal 9) are
closed. See the hardware manual for more information.

Off

One or more customer interlocks or the coast/DB contact is open.

Drive Ready

On

Drive is ready to run or jog. All customer interlocks are closed, the coast/DB
contact is closed, and there are no faults.

Off

Drive is not ready. See chapter 7 for diagnostics information.

Running

On

The contactor is closed and the motor armature is energized in either run or jog
mode. The drive is running.

Off

The contactor is open and the drive is not running.

Current Limit
Torque Limit

On

Drive is operating at the maximum allowable current or torque.

Off

Drive is not at the maximum allowable current or torque.