Basics of Configuring the Drive Using the OIM

4-1

C

HAPTER

4

Basics of Configuring the Drive

Using the OIM

Configuring the drive customizes it for your application. You can use the

OIM

,

WebPak CS software, or network to configure the drive. This chapter describes how to
use the

OIM

to configure the drive, including:

access parameters and make changes to them

restore factory default values for the parameters

self-tune the drive (which lets the drive configure some parameters for you)

use a password to protect your configuration

save changes to parameters

Appendix A of this manual lists full menu paths for accessing parameters. For
parameter descriptions, see the software manual.

4.1

Types of Parameters

Parameters can be inputs or outputs, tunable or configurable, and retentive or
non-retentive.

Input: You can change the value of the parameter through the

OIM

.

Output: Provides output information. Value cannot be changed through the

OIM

.

Tunable: Parameter value can be changed when the drive is running.

Configurable: Parameter value cannot be changed when the drive is running.

Retentive: Parameter value is stored in the drive even when power is off. To save
changes to the values, a Memory Save must be performed before removing power.

Non-retentive: Changes to the parameter value are not saved when power is
removed.