4 scaling values displayed on the oim – Rockwell Automation WebPak 3000  User Guide User Manual

Page 22

Advertising
background image

3-4

WebPak 3000 OIM User Guide

3.4

Scaling Values Displayed on the OIM

You can scale speed and load units to match your application requirements. You can
select from pre-defined units, or configure your own units through the

OTHER

option.

(

OTHER

is available only for speed units.) Scaling these units affects only the

OIM

display.

If you do not change these values, they are set to the defaults of:

RPM

for speed units

%

FLA

for load units

The scaling options are:

Speed units:

RPM

, %, or

OTHER

Load units: %

FLA

or

AMPS

User units affect the monitor mode displays, including display of the serial and keypad
references and the parameters listed in table 3.1.

Table 3.1 – Parameter Displays That are Affected by Scaled Units

Parameter Displays Affected by Speed Units

LINE

SPEED

(P.188)

SPD

LOOP

ERROR

(P.297)

DIAMETER

/

TAPER

IN

TP

(P.192)

SPD

LOOP

FEEDBACK

(P.296)

ANALOG

TACH

FEEDBACK

(P.291)

SPD

LOOP

LAG

OUTPUT

(P.298)

CURRENT

COMPOUND

TP

(P.293)

SPD

LOOP

REFERENCE

(P.295)

JOG

RAMP

OUTPUT

(P.294)

SPD

SOURCE

SELECT

OUT

(P.193)

JOG

SPEED

(P.012)

SPEED

RAMP

INPUT

TP

(P.198)

MAXIMUM

SPEED

(P.004)

SPEED

RAMP

OUTPUT

(P.199)

MINIMUM

SPEED

(P.003)

STOP

SPEED

THRESHOLD

(P.113)

ENCODER

FEEDBACK

(P.292)

TRIM

OUTPUT

(P.197)

Parameter Displays Affected by Load Units

CML

ERROR

(P.398)

SPD

LOOP

OUTPUT

(P.299)

CML

FEEDBACK

(P.397)

TORQUE

REFERENCE

(P.189)

CML

REFERENCE

(P.396)

Advertising