P.510) – Rockwell Automation WebPak 3000 User Guide User Manual
Page 51
Advertising
Using Quick Start
5-15
MOTOR
HOT
FLD
AMPS
(P.510)
Sets the motor
nameplate value of
the rated hot field
amps. This input is
the basis of field
current scaling.
Parameter Range:
0.11 to
INSTALLED
SUPPLY
RATING
(4.00, 10.00, or
20.00
AMPS
)
Default Setting:
0.01
AMPS
Parameter Type:
Configurable
If the factory defaults are restored, or if a valid value has not yet been entered for
this parameter, the DC field voltage is fixed at 150 V on a 230VAC line, or at 300V
on a 460VAC line.
!
ATTENTION: The incorrect configuration of
MOTOR
HOT
FLD
AMPS
(P.510)
can cause a motor overvoltage condition. Configure
MOTOR
HOT
FLD
AMPS
to the motor’s nameplate value. Failure to observe this precaution can
result in bodily injury and damage to the equipment.