Rockwell Automation GV3000/SE AC Bookshelf Drive Hardware Ref, Installation, and Troubleshooting User Manual
Page 30

3-2
GV3000/SE AC Bookshelf Drive Hardware Reference, Version 6.06
•
Do not install the drive above 1000 meters (3300 feet) without derating output
power. For every 91.4 meters (300 feet) above 1000 meters (3300 feet), derate the
output current 1%.
•
Verify that the drive location will meet the environmental conditions specified in table
3.1.
Table 3.1 – Environmental Conditions
Condition
Specification
Operating Temperature (Ambient)
0
°
to
+
40
°
C
(
32
°
to
104
°
F
)
coolant air
inlet temperature at heatsink
Derating factor at 45
°
C (113
°
F)
ambient: Output current by 7.5%
Derating factor at 50
°
C (122
°
F)
ambient: Output current by 15%
Storage Temperature (Ambient)
-25
°
C to +55
°
C (-77
°
to +131
°
F)
Transportation Temperature (Ambient)
-25
°
C to +70
°
C (-77
°
to +158
°
F)
(+70
°
C (+158
°
F) during max. 24 hrs)
Humidity
Maximum: 50% at 40
°
C (104
°
F)
unlimited
Maximum: 90% at 20
°
C (68
°
F) during
maximum 30 days/year
75% average
No condensation