GV3000/SE AC Bookshelf Drive Hardware Reference, Version 6.06

Do not install the drive above 1000 meters (3300 feet) without derating output
power. For every 91.4 meters (300 feet) above 1000 meters (3300 feet), derate the

output current 1%.

Verify that the drive location will meet the environmental conditions specified in table
3.1.

Table 3.1 – Environmental Conditions

Condition

Specification

Operating Temperature (Ambient)

0

°

to

+

40

°

C

(

32

°

to

104

°

F

)

coolant air

inlet temperature at heatsink
Derating factor at 45

°

C (113

°

F)

ambient: Output current by 7.5%
Derating factor at 50

°

C (122

°

F)

ambient: Output current by 15%

Storage Temperature (Ambient)

-25

°

C to +55

°

C (-77

°

to +131

°

F)

Transportation Temperature (Ambient)

-25

°

C to +70

°

C (-77

°

to +158

°

F)

(+70

°

C (+158

°

F) during max. 24 hrs)

Humidity

Maximum: 50% at 40

°

C (104

°

F)

unlimited
Maximum: 90% at 20

°

C (68

°

F) during

maximum 30 days/year
75% average
No condensation