Wiring the Regulator Board Terminal Strip and the Output Relay Terminal Strip

7-3

Figure 7.1 – Two-Wire Start/Stop Sample Control Wiring

+/- 10, 0 to 10 VDC Speed or Torque Reference

Isolated Reference Ground

7

10

11

12
13

14
15

16
17

19

20

22
23
24

9

21

+15 VDC
Phase A

Phase A Not

Phase B

Phase B Not
Regulator Common

4
5

6

8

25

18

0 to 10 VDC Analog Output
Analog Output Return
Isolated Reference Voltage

0/4 to 20 mA Speed or Torque Reference

+24 VDC Supply
Digital Input 8 (Local/Remote)
Digital Input 7 (Ramp 1/ Ramp 2)

Digital Input 6 (Forward/Reverse)
Digital Input 5 (Function Loss)
Digital Input 4 (Run/Jog)
Digital Input 3 (Fault Reset)
Digital Input 2 (Stop)
Digital Input 1 (Start)
+24 VDC Common

FWD

REV

Function Loss

Start/Stop

Reset

Run

Jog

Important: A maintained function loss switch

should be used if P.054 (Level Sense Start
Enable) = ON and P.026 (Function Loss

Response) = 1.

Figure 7.2 – Three-Wire Start/Stop Sample Control Wiring

+/- 10, 0 to 10 VDC Speed or Torque Reference

Isolated Reference Ground

7

10

11

12
13
14
15

16
17

19

20

22
23
24

9

21

+15 VDC
Phase A

Phase A Not

Phase B

Phase B Not

Regulator Common

4
5

6

8

25

18

0 to 10 VDC Analog Output
Analog Output Return
Isolated Reference Voltage

0/4 to 20 mA Speed or Torque Reference

+24 VDC Supply

Digital Input 8 (Local/Remote)
Digital Input 7 (Ramp 1/ Ramp 2)

Digital Input 6 (Forward/Reverse)
Digital Input 5 (Function Loss)
Digital Input 4 (Run/Jog)
Digital Input 3 (Fault Reset)
Digital Input 2 (Stop)
Digital Input 1 (Start)
+ 2 4 V D C C o m m o n

FWD

REV

Function Loss

Stop

Start

Reset

Run

Jog

Important: A maintained function loss switch

should be used if P.054 (Level Sense Start
Enable) = ON and P.026 (Function Loss

Response) = 1.