Selecting a braking resistor, 2 selecting a braking resistor – Rockwell Automation GV3000/SE AC Bookshelf Drive Hardware Ref, Installation, and Troubleshooting User Manual

Page 67

Advertising
background image

Wiring Optional User-Supplied Braking Resistors

8-3

8.2 Selecting a Braking Resistor

The maximum braking power is defined by the maximum braking current and the

maximum DC voltage (750 V). To determine the correct braking resistor for your drive,

refer to table 8.2.

Table 8.2 – Selecting a Braking Resistor

Drive M/N

Braking Power

1

Maximum

Braking

Current

Power

Module Input

Voltage

Turn-On

Voltage

Turn-Off

Voltage

Minimum

Allowed

External

Braking

Resistor

Continuous

25% Duty

Cycle

31ER40xx

31ET40xx

4.5 kW

4.5 kW

6 A

460 V

750 V

720 V

125.0

38ER40xx

38ET40xx

4.5 kW

4.5 kW

6 A

460 V

750 V

720 V

125.0

55ER40xx

55ET40xx

4.5 kW

4.5 kW

6 A

460 V

750 V

720 V

125.0

85ER40xx

85ET40xx

4.5 kW

4.5 kW

6 A

460 V

750 V

720 V

125.0

126ER40xx

126ET40xx

7.5 kW

7.5 kW

10 A

460 V

750 V

720 V

75.0

150ER40xx

150ET40xx

7.5 kW

7.5 kW

10 A

460 V

750 V

720 V

75.0

240ER40xx

240ET40xx

11 kW

11 kW

15 A

460 V

750 V

720 V

50.0

300ER40xx

300ET40xx

15 kW

15 kW

20 A

460 V

750 V

720 V

37.5

430ER40xx

430ET40xx

22 kW

22 kW

30 A

460 V

750 V

720 V

25.0

1

The turn-on and the turn-off voltage and the braking power is proportional to the AC line voltage (specified

in parameter H.021 or U.018).

Advertising