76

Rockwell Automation Publication ENET-IN002F-EN-P - January 2014

Chapter 3 Install a 1769 EtherNet/IP Adapter

10. Locate the downloaded .zip file and extract it to a temporary directory.

11. Use the ControlFlash utility to install the firmware.

Enable the Web Pages

The adapter’s web pages are disabled by default and are disabled when the adapter
is returned to the factory default settings. Complete these steps to enable the web
pages.

1. Set the rotary switches to 000.

2. Apply power to the adapter.

The MOD LED flashes red and the module is inoperable.

3. Set the rotary switches to a valid IP address (not 000 or 888).

4. Cycle power to the adapter.

When the module completes powerup, the web pages are enabled and can
be accessed by entering the module’s IP address into a Web browser.

The Configuration pages (Device Identity, Network Configuration and Device
Services) are password protected. By default they can be accessed with:

Username = administrator
Password = the adapter’s serial number (listed on the adapter’s home page)

If the above procedure is performed while the web pages are already enabled, they
continue to be enabled and the password is reset to the adapter’s serial number.

Disable Web Pages

The adapter’s web pages can be disabled using the check box on the Device
Services page in the Configuration folder.

Advertising