Chapter 1 Prepare the Kinetix 5500 Drive Hardware

Wire Drive Connectors

Kinetix 5500 servo drives are capable of 200V-class (single/three-phase) and 400V-class (three-phase) operation.
This wiring diagram is for 200/400V-class, three-phase operation. For additional interconnect wiring diagrams,
refer to the Kinetix 5500 Servo Drives User Manual, publication

2198-UM001

.

Interconnect Wiring Diagram

Interconnect Diagram Notes

Note

Information

1

AC (EMC) line filter is required for EMC compliance. Place line filter as close to the drive as possible and do not route very dirty wires in wireway. If routing in wireway is
unavoidable, use shielded cable with shields grounded to the drive chassis and filter case. For AC line filter specifications, refer to Kinetix Servo Drives Specifications Technical
Data, publication

GMC-TD003

.

2

Terminal block is required to make connections.

3

Cable shield clamp must be used to meet CE requirements.

4

PE ground connection bonded to the panel must be used to meet CE requirements.

5

DC connector covered with protective knockout is default configuration. Wiring the DC connector does not apply to standalone drives.

6

Internal shunt wired to the RC connector is default configuration. Remove internal shunt wires to attach external shunt wires.

7

Default configuration for ground screws is for grounded power at user site. For ungrounded or corner-grounded power, remove the screws. Refer to Ground the Kinetix 5500
Drive on

page 17

for more information.

DATA +/EPWR+

DATA -/EPWR-

L3

L2

L1

24V_COM

+24V

2

1

MBRK -

MBRK +

DC+

DC-

D+

D-

IN1

COM

IN2

SHLD

1

2

4

3

2

1

1

2

3

4

MBRK -

MBRK +

U

V

W

2

1

4

3

2

1

DC+

SH

195…264V AC rms or

324…528V AC rms

Three-phase Input

Bonded Cabinet Ground Bus *

Control Power
(CP) Connector

PE Ground
Note 4

Mains AC Input
(IPD) Connector

Input Fusing *

* Indicates User Supplied Component

2198-Hxxx-ERS

Kinetix 5500 Drives

Chassis

Note 2

Ground Screws
Note 7

Customer Supplied

+24V DC

Power Supply *

Motor Brake

(BC) Connector

Three-phase
Motor Power
Connections

Motor Power

(MP) Connector

Cable Shield

Clamp

Note 3

DC Bus
(DC) Connector
Note 5

Shunt
(RC) Connector

Motor Feedback

(MF) Connector

Digital Input

(IOD) Connector

Motor Brake
Connections

Motor Feedback
Connections

Registration and
Home Input
Connections

2198-DBxx-F

Three-phase

AC Line Filter

Note 1

Internal Shunt

Note 6