26

Rockwell Automation Publication IASIMP-QS035A-EN-P - December 2012

Chapter 1 Prepare the Kinetix 5500 Drive Hardware

Apply the Single Motor Cable Shield Clamp

Factory-supplied 2090-Series single motor cables are shielded, and the braided cable shield must terminate at the
drive during installation. A small portion of the cable jacket has been removed to expose the shield braid. The
exposed area must be clamped (with the clamp provided) at the bottom front of the drive.

This procedure assumes you have completed wiring your motor power, brake, and feedback connectors and are
ready to apply the cable shield clamp.

Follow these steps to apply the motor cable shield clamp.

1.

Loosen the clamp screws and remove at least one of the screws.

SHOCK HAZARD: To avoid hazard of electrical shock, make sure shielded power cables are grounded according to
recommendations.

Motor Cable

Shield Clamp

2198-KITCON-DSL

Motor Feedback

Connector Kit

Motor Power
(MP) Connector

Motor Brake
(BC) Connector

Exposed shield braid
under clamp.

Cable clamp screws
tightened.

Kinetix 5500 Servo Drives

(frame 1) Front View

2090-CSBM1DF-18AAxx
Motor Cable

Feedback cable routed

around the shield clamp.

18 AWG Cable Installation

TIP

When the drive/motor combination calls for 18 AWG cable, the feedback cable routes around the motor cable shield clamp.