Rockwell Automation Logix5000 Control Systems: Connect Kinetix 5500 Drives on EtherNet/IP Network Quick Start User Manual

Page 27

Advertising
background image

Rockwell Automation Publication IASIMP-QS035A-EN-P - December 2012

27

Prepare the Kinetix 5500 Drive Hardware Chapter 1

2.

Position the exposed portion of the cable braid directly in line with the clamp.

3.

Tighten the clamp screws to a torque value of 2.0 N•m (17.7 lb•in) max.

4.

Repeat

step 1

through

step 3

for each drive in multi-axis configurations.

Motor Cable

Shield Clamp

Motor Power
(MP) Connector

Motor Brake
(BC) Connector

Exposed shield braid
under clamp.

Cable clamp screws
tightened.

Feedback cable routed

within the shield braid.

Kinetix 5500 Servo Drives

(frame 2 or 3) Front View

2198-KITCON-DSL

Motor Feedback

Connector Kit

Retention Screw

(loosen, do not remove)

Clamp features apply to all

frame sizes.

Torque clamp screws to

2.0 N•m (17.5 lb-in), max

2090-CSBM1DF-14AAxx or
2090-CSBM1DF-10AAxx Motor Cables

14 and 10 AWG Cable Installation

TIP

When the drive/motor combination calls for 14 or 10 AWG cable, the feedback cable routes along with the power and brake wiring.

Advertising