Chapter 2 Add a Kinetix 5500 Drive to a Logix Designer Application

7.

Configure the new drive.
a. Type the drive Name.
b. Select an Ethernet Address option.

In this example, the Private Network
address is selected.
c. Enter the address of your

EtherNet/IP module.

In this example, the last octet of the address is 1. The IP address must match the IP address configured on

page 29

.

8.

Click OK to close the New Module dialog box.

Your 2198-H

xxx-ERS servo drive appears in the Controller Organizer

under the Ethernet controller in the I/O Configuration folder.

9.

Click Close to close the Select Module Type dialog box.

10.

Right-click the 2198-H

xxx-ERS servo drive you just created and choose

Properties.

The Module Properties dialog box opens.

11.

Click the Associated Axes
tab.

12.

Click New Axis.

The New Tag dialog box
opens.