5

I

NSTALLING

F

ACTORY

T

ALK

A

SSET

C

ENTRE

AGENTS

61

• •

After the Disaster Recovery agent installation is complete, the installation for the
FactoryTalk AssetCentre Agent begins.

To install the FactoryTalk AssetCentre agent:

1. Follow the on-screen instructions.

RSLogix 5000 Compare installer

See “Installing the FactoryTalk AssetCentre Disaster Recovery agent” on page 53 for the steps to
get to this part of the installation.

To be able to perform compares between Logix Designer or RSLogix 5000 projects, the
Disaster Recovery agent uses version 3.10 or later of the RSLogix 5000 Compare utility.

To install the RSLogix 5000 Compare utility:

1. Follow the on-screen instructions.

2. If you have RSLogix 5000 software or Logix Designer application installed on the

computer on which you are installing the FactoryTalk AssetCentre agents, you can
add a Compare option to the application Tools menu. (This requires version 13 or later
of the application.) To do this, select the Add Compare Tool to RSLogix 5000 Tools
menu
check box. Click Next.

3. On the Select Installation Folder screen, be sure to select Everyone. This is very

important to the proper functioning of the agent.

You can also choose where the compare utility is installed. By default, the utility is
installed in the C:\Program Files\Rockwell Software\RSLogix 5000 Compare folder.
You can change this folder by typing a new path in the Folder field, or by clicking the
Browse button.

4. Click Next.

5. Continue to follow the on-screen instructions.

Using the Windows Firewall Configuration Utility

See “Installing the FactoryTalk AssetCentre Disaster Recovery agent” on page 53 for the steps to
get to this part of the installation.

The Windows Firewall Configuration Utility will run whether you are using the firewall
or not.

If your Windows Firewall/Internet Connection Sharing (ICS) service is stopped or is
disabled, the FactoryTalk AssetCentre Windows Firewall Configuration window will

FTAC-IN005A-EN-E.book Page 61 Monday, March 4, 2013 4:03 PM

Advertising