Kontron CG2200 Carrier Grade Server User Manual

Page 104

Advertising
background image


97

Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

Table 9. System Status LED Definitions

Color

State

Criticality

Description

Green

Solid on

System OK

System booted and ready

Green

Blink

Degraded

System degraded:

Non-critical temperature threshold asserted

Non-critical voltage threshold asserted

Non-critical fan threshold asserted

Fan redundancy lost, sufficient system

cooling maintained. This does not apply
to non-redundant systems.

Power supply predictive failure

Power supply redundancy lost. This does

not apply to non-redundant systems.

Corrective errors over a threshold of 10 and
migrating to a mirrored DIMM (memory
mirroring). This indicates the user no longer
has spare DIMMs indicating a redundancy
lost condition. The corresponding DIMM
LED should light up

Amber

Blink

Non-critical

Non-fatal alarm – system is likely to fail:

Critical temperature threshold asserted

CATERR asserted

Critical voltage threshold asserted

VRD not asserted

SMI timeout asserted

Amber

Solid on

Critical, non-
recoverable

Fatal alarm – system has failed or shut down

CPU missing

Thermal Trip asserted

Non-recoverable temperature threshold

asserted

Non-recoverable voltage threshold

asserted

Power fault/power control failure

Fan redundancy lost, insufficient system

cooling. This does not apply to non-
redundant systems.

Power supply redundancy lost,

Advertising