Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

Figure 13. Memory DIMM Installation

3.3.7 Replacing or Removing Memory DIMMs

NOTE: To reduce the risk of electrostatic discharge (ESD) damage to the processor or the DIMM, be sure to

follow these procedures:
1) Touch the metal chassis before touching the DIMM or server board.
2) Keep part of your body in contact with the metal chassis to dissipate the static charge while handling
the DIMM.
3) Avoid moving around unnecessarily.
4) Use a ground strap attached to the front panel (with the bezel removed).

To remove a DIMM from the S2600CO server board, follow these steps:

1.

Power down the server and remove all peripheral devices and the power cord(s)

2.

Remove the chassis cover. For instructions, see “Removing the Cover”.

3.

Remove the right-side riser card assembly. For instructions see “Removing a Riser Card Assembly”.

4.

Remove the processor air duct. For instructions, see “Removing the Processor Air Duct”.

5.

Open the DIMM slot levers for the DIMM you want to remove. (Figure 13)

6.

Using both hands, hold the DIMM by the edges and lift it up from the slot. Store the DIMM in an anti-

static package.

7.

If you are installing a replacement DIMM in this slot, return to Step 5 in “Installing Memory DIMMs”.

Otherwise, replace the air duct, riser card assemblies, and chassis cover if you have completed all
work inside the server.