Kontron CG2200 Carrier Grade Server User Manual

Page 30

Advertising
background image


23

Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

Figure 12. Removing the Processor Air Duct

3.2.8 Re-Installing the Processor Air Duct

The air duct is required to ensure proper air flow within the chassis, so be sure that it is in place again
before re-installing the chassis cover.

1. Place the processor air duct over the processor sockets and DIMMs. Align the standoff on the top right

with the captive screw on the support cross bar. Tighten the screw to secure the air duct.

2. Re-install the riser card assembly. For instructions, see “Re-Installing a Riser Card Assembly”.

3. Replace the chassis cover and reconnect all power cords and external peripheral devices. For

instructions, see “Re-Installing the Cover”.

3.3

Internal System Components Configuration and Installation

Procedures

This section covers separately-orderable components that must be installed for your server to operate. It
also covers replacing these components and where relevant, such as with memory DIMMs, how to
configure them.

You install your separately-orderable DIMMs and processors on the Intel® Server Board S2600CO, which
is the baseboard for this server.

NOTE: Be sure to read the following information about the configuration rules and memory feature options

before you begin.

3.3.1 Configuring Memory DIMMs

The memory DIMM slots are located in two separate banks on the S2600CO server board. Detailed
information about the memory subsystem in the CG2200 server can be found in the Intel® Server Board
S2600CO Family Technical Product Specification
located on the Kontron support website