9145E10G NID Software User’s Manual

IP/SNMP Agent Configuration

19

3.1.4.1 Adding a Host IP

To Add a Host IP, on the Trap/Notifdication Destination Table (Figure 3-7), type (A)dd and press
Enter. The Edit Trap/Notification menu (Figure 3-8.) opens.

1. Type in the Host IP address to add to the Trap/Notification Destination Table, and press

Enter.

11. Enter the Trap/Notification Port. The default value is 162 for regular SNMP managers,

163 is for CanogaView. Any port numbers from 1 to 65535 can be used to receive traps.
Check with your IT manager to ensure the port setting is correct.

12. Use Space to select the Notification Type for this SNMP host. Selections are: V1-Trap,

V2c-Trap, V2c-Inform, V3-Trap, and V3-Inform.

NOTE:

Each Notification Type has a different configuration procedure. Fol-
low the specific procedure for the Notification Type selected.

Figure 3-8. Add Trap/Notification Type Menu

Canoga Perkins Corp. Ethernet Network Interface Device 04-JAN-2010
9145E10G-527-2-0 V01.00 F31 01:45:14
-----------------------------EDIT TRAP/NOTIFICATION TYPE-----------------------

IP Address :
Trap/Notification Port :
Notification Type :

Enter Managing Host IP address
------------------------------------Messages-----------------------------------