0 system alarms, Figure 6-1. system alarm screen, System alarms & logs – CANOGA PERKINS 9145E10G NID Software Version 1.0 User Manual

Page 83: Chapter 6 system alarms & logs

Advertising
background image

System Alarms & Logs

9145E10G NID Software User’s Manual

71

6.0 System Alarms

Use the System Alarms Screen to view alarms and faults on the 9145E10G.

To view alarm status, select System Alarms (4) from the Main Menu and press Enter. The Sys-
tem Alarms Screen (Figure 6-1.) opens. Press Esc to return to the Main Menu.

Figure 6-1. System Alarm Screen

Canoga Perkins Corp. Ethernet Network Interface Device 04-JAN-2010
9145E10G-527-2-0 V01.00 F31 01:45:14
-------------------------------------SYSTEM ALARMS-----------------------------
Link Remote Fault Optic Transmitter
User Port *** Down *** No OK
Network Port Up No OK
MP Port (Gig) Disabled N/A N/A
MGMT UTP Port *** Down ***

Link Loss Fwd User->Net No
Link Loss Fwd Net->User No

AC 120/240 PS A Status OK 5.22 Volts Output (4.83 < OK < 5.49)
AC 120/240 PS B Status Bad 0.00 Volts Output (4.83 < OK < 5.49)
Main Board Voltages All mainboard voltages OK
Fan Status Both Fans Ok
Temperature Status OK 29.5C (0.0C < OK < 70.0C)

Hit 'ESC' to return to previous menu
----------------------------------Messages-------------------------------------

Chapter 6

System Alarms & Logs