Service OAM

9145EMP NID Software User’s Manual

SOAM Configuration

133

Figure 11-6 SOAM Configuration

NOTE: You can perform system-level configuration before or after you configure

Maintenance Domains or other entities.

4. On the SOAM System Level Configuration screen (Figure 11-7), type 1 and press Enter.

5. Use the Space bar to select Enabled or Disabled and press Enter. If Service OAM proce-

dures are disabled for the system, no Service OAM packets are captured and processed.
Instead, all Service OAM packets received by the 9145EMP NID are transparently for-
warded, using the same rules as for data plane traffic.

6. To select a Chassis ID Format, type 2 and press Enter. Select one of the following set-

tings:

MAC Address, and press Enter. The Chassis ID value is read only. You cannot
change the value on this screen.

Network Address, and press Enter. The Network Address value is read only. You
cannot change the value on this screen.

Locally Assigned, and press Enter. This selection allows you to enter a custom
string.

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145EMP-761-0-0 V07.11 F7 Canoga 9145EMP 32 device 05:15:27
------------------------------SOAM CONFIGURATION-------------------------------

1) System level configuration

2) Maintenance Domains (MDs)
3) Maintenance Associations (MAs)
4) Maintenance Entity Groups (MEGs)
5) Maintenance End Points (MEPs)
6) Maintenance Intermediate Points (MIPs)

7) Configuration Error List

Select [1-7]:

------------------------------------Messages-----------------------------------