CANOGA PERKINS 9145EMP NID Software Version 3.1 User Manual

Page 37

Advertising
background image

System Configuration

9145EMP NID Software User’s Manual

Trap Configuration

25

The System Log contains the log of all enabled Trap events.

1. To configure Traps, select Trap Configuration (2) from the System Configuration menu.

The Trap Configuration screen (Figure 3-15) opens.

2. Select the number of the trap group to change and press Enter. Press the Space bar to

select Log Only, Send Only, Both Log And Send, or Disabled.

The Master Trap Control setting will override all other trap settings. For example, if the
Master Trap Control is set to Log Only, rather than set to Both Log And Send (as shown),
all the other traps will only log alarm events, regardless of the individual trap settings. If
the Master Trap Control is set to Log And Send, the individual traps will perform
according to their individual settings. Setting the Master Trap Control setting to Disabled
will disable all traps.

3. Press Enter to close the editing function and then press Esc to return to the System

Configuration screen.

cpFanSlow

cpFanStatus.my

cpFanFailed

cpFanStatus.my

cpTemperatureOverHighThresholdAlarm

cpStatus.my

cpTemperatureHighThresholdAlarmCleared

cpStatus.my

cpTemperatureWarningApproachingHighThreshold cpStatus.my

cpTemperatureHighThresholdWarningCleared

cpStatus.my

cpTemperatureAlarmUnderLowThreshold

cpStatus.my

cpTemperatureLowThresholdAlarmCleared

cpStatus.my

cpTemperatureWarningApproachingLowThreshold cpStatus.my

cpTemperatureLowThresholdWarningCleared

cpStatus.my

SFP Traps

cpSfpRemoved

cpSfpStatus.my

cpSfpInsertedInvalid

cpSfpStatus.my

cpSfpInsertedValid

cpSfpStatus.my

cpSfpTxOk

cpSfpStatus.my

cpSfpTxWarning

cpSfpStatus.my

cpSfpTxFailure

cpSfpStatus.my

Service OAM Traps

cpSoamXConnCcm

cp_soam_ext.my

cpSoamErrorCcm

cpSoamRMepCcm

cpSoamMacStatus

cpSoamRDIDetect

cpSoamAISDetect