System Configuration

9145EMP NID Software User’s Manual

IP/SNMP Agent Configuration

17

6. To change the SNMP Protocol parameters, type 4 and press Enter. Press the Space bar:

V1/V2c/V3, V1/V2c, or V3 using the Space Bar. Press Enter to select the parameter.

Figure 3-6 Edit Host Access screen

7. To change V1/V2c Read Community, type 5 and press Enter. Type the desired V1/V2c

Read Community and press Enter.

8. To change the V1/V2c Write Community, type 6 and press Enter. Type the desired V1/

V2c Write Community and press Enter.

9. To change the V1/V2c Access Level, type 7 and press Enter. Press the Space bar to

select Operator, Supervisor, or Observer. Press Enter to select the parameter.

10. Press Esc to return to the Host Access Table screen.

NOTE: SNMP V3 security parameters are configured per user account on the Edit User

Account screen. From the System Configuration screen type 4 and press Enter to
open the Account Configuration screen, then type E to edit an account.


Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145EMP-761-0-0 V07.11 F7 Canoga 9145EMP 32 device 11:51:16
----------------------------------EDIT HOST ACCESS-----------------------------

Managing Host IP :
IP Mask Size :
1. Telnet Access :
2. FTP Access :
3. SNMP Access :
4. SNMP Protocol :
5. V1/V2c Read Community :
6. V1/V2c Write Community :
7. V1/V2c Access Level :

Enter Managing Host IP address

------------------------------------Messages-----------------------------------