CANOGA PERKINS 9145EMP NID Software Version 3.1 User Manual

Page 159

Advertising
background image

Service OAM

9145EMP NID Software User’s Manual

Maintenance Entity Groups

147

To remove a peer MEP, type 2 and press Enter. You are prompted for the MEP ID
number. Type the number and press Enter.

When all the peer MEPs have been configured, type A to accept and press Enter.

Press Esc to return to the Maintenance Entity Group Attributes screen

8. You can change the Permissions (Sender ID). Type 5 and press Enter. Select None,

Chassis, Manage, ChassisManage, or Defer, and press Enter.

9. When you are finished, type A to accept and press Enter.

10. Press Esc to return to the Maintenance Entity Group List screen.

Figure 11-16 Maintenance Entity Group Attributes screen

Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2010
Model 9145EMP-761-0-0 V11.02 F11 00:11:01
---------------------MAINTENANCE ENTITY GROUP ATTRIBUTES------------------------

MEG ID:100 Name: test-meg
Name Format: ICC-based Format
Level: 2
1) CCM Interval: 1 sec

VLAN Tag Type: C-Tag
VLAN Multiplexing record. 100

VLAN List: N/A

2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.

4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None

Select [1-6] for attributes:

------------------------------------Messages-----------------------------------