Diagnostics
9145EMP NID Software User’s Manual
PING Generation
47
5. To enter the Ping Payload Size, type 5 and press Enter. Type a value between 40 and
9950. To send packets greater than 1518 (payload size greater than 1472), the DF (Don't
Fragment) bit must be set or the packet will be fragmented (sent as multiple packets of
size 1518).
6. To change the Ping DF Bit setting, type 6 and press Enter. See the Ping Payload size for
explanation.
7. When you are finished entering values, type 7 to start pinging and press Enter. The PING
test starts (Figure 4-5).
8. When the test is complete, press Esc to return to the PING Generation screen.
Figure 4-5 PING Generation - In Progress screen
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145EMP-761-0-0 V07.11 F7 11:20:59
-------------------------------PING GENERATION---------------------------------
PING in progress
Ping Address : 172.16.2.132
Ping Count : 0
Ping VLAN type : S-Tag
Ping C-VLAN ID : 0
Ping S-VLAN ID : 100
Pinging 172.16.2.132 from 172.16.151.61 with 40 bytes.
Reply from 172.16.2.132 Seq #0 time <10 ms TTL=128
Reply from 172.16.2.132 Seq #1 time <10 ms TTL=128
Reply from 172.16.2.132 Seq #2 time <10 ms TTL=128
Reply from 172.16.2.132 Seq #3 time <10 ms TTL=128
Press Escape to stop Pinging...