CANOGA PERKINS 9145EMP NID Software Version 3.1 User Manual
Page 84
9145EMP NID Software User’s Manual
Port Information
Link Aggregation
72
4. Type 6 to go to the LAG Port Partner Attributes screen (Figure 5-21).
5. In the LAG Port Partner Attributes screen, set the following four attributes to Yes, as in
Figure 5-21:
•
8) Aggregation
•
9) Synchronization
•
10) Collecting
•
11) Distributing
Figure 5-21 Configuring Static LAG: LAG Port Partner Attributes screen
6. Return to the LAG Ports List screen (Figure 5-16) and repeat steps 2-5 for NET2.
Canoga Perkins Corp. Ethernet Network Interface Device 02-JUN-2010
Model 9145EMP-761-0-0 V07.11 F7 15:23:33
-------------------------LAG PORT PARTNER ATTRIBUTES----------------------------
Interface: NET1
Churn is detected: No
Oper system address: 00:40:2A:04:E5:47 1) System address: 00:40:2A:04:E5:47
Oper system priority: 32768 2) System priority: 32768
Oper key: 1 3) Admin key: 1
Oper port: 0 4) Admin port: 0
Oper port priority: 32768 5) Admin port prio: 32768
Oper LACP activity: Passive 6) LACP activity: Passive
Oper LACP timeout: Long 7) LACP timeout: Long
Oper aggregation: No 8) Aggregation: Yes
Yes
Yes
Yes
Oper synchronization: No 9) Synchronization: Yes
Yes
Yes
Yes
Oper collecting: No 10) Collecting: Yes
Yes
Yes
Yes
Oper distributing: No 11) Distributing: Yes
Yes
Yes
Yes
Oper defaulted: No 12) Defaulted: No
Oper expired: No 13) Expired: No
Select [1-13] for attributes:
------------------------------------Messages-----------------------------------