Wj-nt204 direct coaxial camera select, Wj-mp204 camera select, Cd alarm list (wj-nt204) – Panasonic WV-CU20 User Manual

Page 107: Alarm reset, Camera preset registration, D pan/tilt, Zoom, Auto pan, Tj) preset, Status display

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

® WJ-NT204 DIRECT COAXIAL CAMERA SELECT

Select the input number to the WJ-NT204 from 1 to 4
and AUX,

WJ-MP204 CAMERA SELECT

When AUX is selected, a 16-button panel appears
where you can select a camera connected to the WJ-

MP204 Data Multiplex Units #1 through #4 while AUX
button disappears. The numbers of buttons will vary

from 16 to 12, 8 or 4 depending on the numbers of the

connected WJ-MP204 units and when the html file is
changed accordingly. To return the panel back to 5-

button, click on any of the input button from 1 to 4 in

the WJ-NT204 DIRECT COAXIAL CAMERA SELECT.

WI-UP204 CAMERA

CONTROL VIEW

CD

ALARM LIST (WJ-NT204)

Displays the alarm list activated on the WJ-NT204

transmitter.

® ALARM RESET

Resets the alarm mode activated on the WJ-MP204 or

WJ-NT204 transmitter.

® CAMERA PRESET REGISTRATION

Select the number and click the SET to register the pre­
set position that is presently displayed of the camera

connected to the WJ-NT204 or WJ-MP204. Position
entry is available up to 64.

(D PAN/TILT

Click on any of the pan/tilt buttons: Up, Down, Right or

Left to move the pan/tilt head of the Combination cam­

era to the desired direction. Click the button repeatedly

as necessary not holding down it.

® ZOOM

Click the button to zoom in or out. Instead holding
down the button, click on it repeatedly as necessary.

TELE: Zooms in the image.
WIDE: Zooms out the image.

CD

FOCUS

Click NEAR or FAR to adjust the focus of the image

manually. Instead holding down the button, click on it

repeatedly as necessary,
NEAR: Manual focusing
FAR: Manual focusing
AUTO: The built-in focus mechanism performs in the

Combination camera.

CD

IRIS

The connected combination camera (option) can be

controlled to close or open the iris by clicking the
[CLOSE] or [OPEN] button under IRIS.
Clicking the [OPEN] or [CLOSE] button will open or
close the camera iris for a specified time, after which
the operation is released automatically.

Clicking the [RESET] button on the screen will reset
the iris of the displayed camera to the factory default

setting. Iris control cannot be retained by keeping the
[OPEN] or [CLOSE] button depressed. You need to

click the [OPEN] or [CLOSE] button again.

® AUTO PAN

The auto pan status of the connected combination

camera (option) can be changed by clicking the [ON]

or [OFF] button under AUTOPAN.

Note: When LOCAL is selected in the camera setup

menu, auto pan is released automatically within 1

minute.

(Tj) PRESET

To move the connected combination camera (option) to
any of 64 preset positions and the HOME position.

Select a preset position number, then press the [SET]
button to move the camera to the position,

@ Status Display

Displays alarm information when an alarm connected to

the WJ-MP204 or WJ-MP204 is activated..

® Image Display

The image supplied from the selected camera is dis­

played.

107

Advertising