■ 400 SETUP
Eight of fundamentals are set up for the system.
The menus 430, 460 and 470 will be replaced with dashed
lines when the unit is set to a receiver.
400 SETUP
410 RE-COHNECTIOtU
420 SERIAL/HOST PORT4.
430 VIDEO SWITCH SETUPl
440 АТП)101
450 VIDEOl
460 ALJUml
470 SEQ.SCAH SETUP!
480 LOCK/MENU PASSWORD!
t!;MOVE ЕЫТ:SELECT ESC:PRV
1. The 400 SETUP menu appears when you press the
ENTER button after selecting it in the 000 TOP menu,
2. Select a menu you wish to set up from the 410, 420,
430, 440, 450, 460, 470, and 480, then press the
ENTER, The selected menu appears.
410 RE-CONNECTION
Re-connection is started by the site that is set to ON for this
setting when a call is interrupted during communication.
This setting is applicable only to the system comprising two
WJ-NT204 units, one for TRANSMITTER and the other for
RECEIVER, and when the call has been made with the
Remote Controller WV-CU20. This does not perform in the
multi-site connection.
410 RE-CONNECTION
RE-CONNECTION : OH OPF
IN СОИ.STATE,NT204 HILL CONNECT
AOAIN IN CASE OF NETWORK
INTERRUPTION.
>: SELECT BSCiPRV
1. Open the 410 RE-CONNECTION menu.
2. Select either ON or OFF with the direction button. The
default setting is ON,
ON: Re-connection is enabled.
OFF: Disabled.
420 SERIAUHOST PORT
Serial and Host ports are set up in this menu.
420 SERIAL/HOST PORT
421 SERIAL DATA PORT!
422 HOST PORT!
T!:MOVE ENT:SELECT ESC:PRV
1. Open the 420 SERIAL/HOST PORT menu.
2, Select a menu you wish to set up from the 421 and 422,
then press the ENTER. The selected menu appears.
421 SERIAL DATA PORT: Select this when the system
comprises a Matrix Switcher (WJ-SX550A/B),
Digital Disk Recorder or other PS'Data devices,
422 HOST PORT: Select this when the system con
nects with a personal computer,
421 SERIAL DATA PORT
The DIP switch #4 on the rear of the unit specifies the
usable serial port from RS-232C or RS-485 (PS’Data). The
settings below must be the same among the devices con
nected in the chain, except the unit #.
421 SERIAL DATA PORT
RATE
4800 8600 19200
DATA BITS:
8 7
STOP BITS:
1 2
PARITY
t
HONE ODD EVEN
MODE ;
PSD
NORMAL
RS485
UNIT
#:002 (002-999)
T!:HOVE
SELECT ESC:PRV
J
1. Open the 421 SERIAL DATA PORT menu.
2. Move the cursor to RATE, then select a Baud rate with
the or ► button.
The default setting is 9600.
4800: 4800 bps (bit per second)
9600: 9600 bps
19200: 19200 bps
40