This selection defines the sensor signal reception to the

unit, and applies for all 8 sensor inputs. Consult the
sensor on the output signal type.

LEVEL: The unit enters and retains the alarm mode

while the sensor signal continues active status,

EDGE (OPEN): The unit enters the alarm mode when

the sensor input changes from the close to open

status.

EDGE (CLOSE): The unit enters the alarm mode when

the sensor input changes from the open to close

status.

462, 463, 464

ALARM DIALING TABLE (Transmitter only)

These tables link between each sensor input and the quick
dial numbers specified in the 300 DIALING REGI. One sen*
sor input lists three quick numbers. When a sensor oper­
ates, the unit dials the first number. If the first destination

could not connect, the unit re-dials the second, and if not
the third. The unit tries dialing up to 3 rounds when ALARM

TYPE is set to EDGE, or does more rounds until the sensor

input is reset when the TYPE is set to LEVEL.This setup is
applied only to the transmitter.

Note: The alarm log may record redundant event when

this setting is changed from one to another.

3. Move the cursor to ALARM AUTO DISC (disconnection)

and select either ON or OFF with the or ► button.
The default setting is ON.

ON: The alarm mode ends when the time elapses in

the ALARM DISC TIMER below,

OFF: Automatic disconnection is disabled.

4. Move the cursor to ALARM AUTO DISC TIMER and

enter a 3-digit number with the numeric buttons.

The unit escapes from the ALARM mode after elapsing
the specified time in this setting. Time range depends
on the ALARM TYPE selection. The time entry is

allowed every 10 second in the range such as 010, 020
and so forth common to LEVEL and EDGE selection.

The default setting is 60S.

0-600S (second): applies to LEVEL selection.

10-600S (second): applies to EDGE selection,

5. Select the applicable day and time for ALARM DIAL­

ING TIME TABLE. The dial numbers are specified in the

menus 462, 463, and 464. You can utilize these time

tables when there are differences in time zone or call­

ing addresses depending on days. For example,

TABLE 1 is used for weekdays while TABLE 2 is used
for holidays with different calling addresses.

5-1 Move the cursor to the “starting day" position on

TABLE 1 line. Press the ENTER repeatedly until the
desired day of the week appears.

5-2 Move the cursor to the "ending day" position on

TABLE 1 line. Press the ENTER repeatedly until the

desired day of the week appears.

5-3 Move the cursor to the “starting time" position on

TABLE 1 line. Enter the time with the numeric but­
tons.

5-4 Move the cursor to the “ending time" position on

TABLE 1 line. Enter the time with the numeric but­

tons,

5-5 Repeat above steps for TABLE 2 and 3.

Notes:

• The times can be entered in the 24-hour system.
• Enter “MON-SUN 00:00-00:00" when you let the

unit work all the time around.

• When you do not apply any of alarm dialing table,

cancel all dial numbers in the corresponding menu

462, 463 or 463 ALARM DIALING TABLE.

[ 00::00-00;00

#2

001

002

003

Oil

012

013

d62 AUUUl DIALING TABLEl

ALARM

1

2

3

4

5

6

7

8

T-Li—+:MOVE ENT ¡SELECT ESCiPRV

1. Open the 462 ALARM DIALING TABLE1 menu,

2. Move the cursor to the dial #1 on the ALARM input 1

line and enter a quick number with the numeric but­

tons, then press the ENTER.

3. Move the cursor to the dial #2 and enter the second

quick number.

4. Move the cursor to the dial #3 and enter the third quick

number.

5, Repeat steps 2

necessary.

through 4 for other ALARM inputs if

465 ALARM PORT SETUP (Transmitter only)

The sensor inputs connected to the rear of the unit can be

enabled or disabled with this setup. EXT can be set only for
the port #8. This setup is applied only to the transmitter.

Similar setup is available at the receiver through the 540
menu during communication.

----- N

465 ALARM

PORT SETUP

PORT HO.

1

ENABLE

DISABLE

2

ENABLE

DISABLE

3

ENABLE

DISABLE

4

ENABLE

DISABLE

5

ENABLE

DISABLE

6

ENABLE

DISABLE

7

ENABLE

DISABLE

8

ENABLE

DISABLE EXT

tli—>ìMOVE

i

—»¡SELECT ESCiFRV

_____ >

1, Open the 465 ALARM PORT SETUP menu.

44