Controller Port [REMOTE]
Connect with a Remote Controller WV-CU20 that only
operates the unit. Connection cable is a 6-conductor
modular type included in the Controller. {RJ-11)

RS-485 Host Port [RS-485 HOST PORT]
Use this when connecting with another WJ-NT204 unit

to operate them from a single controller such as a PC
through the RS-485 daisy chain. Make certain to set the

DIP switch #9 on the front panel to OFF when using this

port. (RJ-11)

RS-485

Host port

RS-485 Data port

m

6 5 4

1 1 1

3 2 1

1 1 1

1 1 1

GNDA B

1 1 1

A BGND

1_1

1_1

TransmitReceive

Straight

For PC

RflJ>

Receive

Transmit

WJ-NT204

®

Setup DIP Switch [SETUP]

A 6-bit DIP switch is provided with the following func­
tion. The default position is marked with V See INSTAL­

LATIONS on how to set these switches.

Bit#

OFF

ON

Function/Note

#1

Open*

Terminate

Termination on Transparent

Receiving side

#2

Open*

Terminate

Termination on Transparent
Transmission side

#3

Receiver*

(Straight)

Transmitter

(Cross)

RS-485 DATA PORT wiring

exchange

#4

RS-485'

RS-232C DATA PORT selection

#5

Open’

Terminate

Termination on Host Receiving

side

#6

Open*

Terminate

Termination on Host Transmission

side

RS-485 Data Port [RS-485 DATA PORT]
Use this when connecting with other PS*Data

(Panasonic Security) devices such as WJ-MP204 Data

Multiplex Unit, WJ-FS409 Video Multiplexer and so forth

to operate them from a Remote Controller through the

RS-485 chain.

The DIP switch #4 on the rear panel must be set to OFF
when using as an RS-485, or to ON as an RS-232C.
The DIP switch #3 on the rear panel changes terminal
wiring either Straight or Crossover as shown below.

(RJ-11)

This switch is set to OFF for a Receiver, and ON for a
Transmitter when CCTV devices are connected.

Straight

(Receiver)

F=T

Crossover

(Transmitter)

j

:

L-

ATAPDH'

DkTA

HCRT

6 5 4

1 1 1

3 2 1

1 1 1

6 5 4

1 I i

3 2 1

1 1 1

1 1 1

GNDA B

1 1 1

A BGND

1 1 1

GNDA B

1 1 1

A BGND

1_1

1_1

1_1

1_1

TransmitReceive

Receive

Transmit

Crossover (Transmitter)

3

TA

KF

For

^ 2

TB,

— Transmit

Matrix
Switcher

c

RA

A

_ RB,

— Receive

WJ-NT204

Straight (Receiver)

For

_

System Controller

ex.) WV-CU360

RS-232C Data Port [RS-232C DATA PORT]
Use this when communicating with other RS-232
devices through D-Sub 9-pin connector. The pin func­

tion is basically the same as the RS-232C HOST port
on the front panel.

RS-232C

DATA PORT

RS-232C Data Port

No.

Signal

name

Function

Direction as seen from

WJ-NT204

1

C D

Receiver carrier

detection

Input

2

R D

Receiving data

Input

3

SD

Sensing data

Output

4

E R

Data connection ready

Output

5

SG

Signal Ground

-

6

D R

Data set ready

Input

7

R S

Request send

Output

8

CS

Send enabled

Input

9

N. C.

(Not used)

(g) Ethernet Port [10BASE-T/100BASE-TX]

Connect the 10/100BASE-T terminal to an Ethernet with
a 10BASE-T or 100BASE-TX cable.

Signal Ground [SIGNAL GND]