i DIP Switch Setting on the Control Site

1. Set the WJ-NT204 Rear DIP Switch as follows. This set­

ting applies when connecting with PS’Data devices
such as System Controller on the Control site.

Bit # 1 : ON/OFF

Bit #2: ON/OFF

Bit#3: OFF

Bit #4: OFF
Bit #5: ON/OFF

Bit #6: ON/OFF

Termination, set to ON at the
end of the RS-485 DATA line,
wise OFF,
Termination, set to ON at the
end of the RS-485 DATA line,
wise OFF.
Straight wiring for RS-485

PORT
RS-485 DATA port is selected.

Termination, set to ON at the
end of the RS-485 HOST line,

wise OFF.

Termination, set to ON at the
end of the RS-485 HOST line,
wise OFF.

chain

other-

chain

other-

DATA

chain

other-

chain

other-

ON

OFF

dido

ddd

WJ-NT204 (Receiver)
SETUP DIP Switch

2 3 4 5 6

L OFF: RS-485 DATA PORT selected

— OFF: Straight wiring for RS-485 DATA PORT

— ON, ON: Termination for DATA Lines

— OFF, OFF: Open for DATA Line

2. Set the DIP Switch and Unit Number Switch on the rear

of the System Controller WV-CU360 as follows. For

details refer to the manual included in the System

Controller.

DIP Bit #5:

ON/OFF

Unit Number: Setto 1.

Termination for RS-485

(PS-DATA), set to ON at the
RS-485 chain end, otherwise
set to OFF.

OFF

□ □ □ □

u u u

System Controller

WV-CU360

1 2 3 4 5 6 7 8

— Set the unit number

— ON: Termination for

RS-485 (PS-Data) Lines

— OFF: Open for Lines

■ PC Connection

Connect the Remote site unit to the PC via a hub with Ethernet straight cables as shown below,

For more details, refer to LAN TYPE CONNECTION on page 66.

Connection to a Client PC via Hub

Combination Cameras (4)

32