Panasonic WV-CU20 User Manual

Page 43

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

452 ON_SCREEN DISPLAY

You can set the display contents in this menu.

452 OH-SCREEN DISPLAY

VIDEO

INPUT DISP.:

ON

OFF

TITLE

DISP. :

ON

OFF

CLOCK

DISP. :

ON

OFF

TIiMOVE

SELECT ESC : PRV

1. Open the 452 ON_SCREEN DISPLAY menu.

2. Move the cursor to VIDEO INPUT DISP. and select ON

or OFF with the or ► button. The default setting is
ON.

ON: Enables the display of the currently designated

video input.

OFF: Disables the display.

3. Move the cursor to TITLE DISP. and select ON or OFF

with the or ► button. The default setting is ON.

ON: Enables the title display.
OFF: Disables the display.

4. Move the cursor to CLOCK DISP. and select ON or

OFF with the or ► button. The default setting is ON.

ON: Enables the time and date display.
OFF: Disables the display.

453 CABLE COMPENSATION (Transmitter only)

Picture quality is lowered as long as the cable is extended
between the transmitter and the camera. Compensation is
applied to the transmitter in three degrees with assumption
that RG'59/U, BELDEN 9259 or equivalent cable is used.
The default setting is S.

453 CABLE

COMPENSA'

CAMERAl;

S

M

L

CAMERA2:

S

M

L

CAMERA3:

S

M

L

CAMERA4:

S

и

L

T4^:MOVE

SELECT ESC: PRV

1. Open the 453 CABLE COMPENSATION menu.

2. Move the cursor to CAMERA 1 and select S, M or L

with the or ► button.

S (Short): Up to 400 m (1 300 ft)
M (Middle): From 400 m {1 300 ft) to 700 m (2 300 ft)
L (Long): From 700 m (2 300 ft) to 900 m (3 000 ft)

3. Repeat above step for the remaining cameras.

460 ALARM (Transmitter only)

Alarm sensors are connected with a transmitter unit, and

are located at where the camera aims or associated

places. If a connected sensor operates, the transmitter unit

will notify the Control site of the alarm activation during
standby mode. Then the unit starts communication to trans­
mit image and audio. The 460 ALARM menu lets you select
and set up the 461 ALARM SETUP, 462 to 464 ALARM

DIALING TABLES and 465 ALARM PORT SETUP. For more
information, see SENSOR OPERATION in APPENDIX.

1. Open the 460 ALARM menu.

460 ALARM

461 ALARM SETUPJ,
462 ALARM DIALING TABLEll
463 ALARM DIALING TABLE21
464 ALARM DIALING TABLE3.T
465 ALARM PORT SETUP4^

T4:MOVE ENT:SELECT ESC:PRV

2. Select 461, 462, 463, 464 or 465 with the A or ▼ but­

ton, then press the ENTER.
The selected menu appears.

461 ALARM SETUP (Transmitter only)

This setup is applied only to the transmitter.

1. Open the 461 ALARM SETUP menu.

461 ALARM SETUP

ALARM

TYPE;

LEVEL

EDGE(OPEN

CLOSE)

ALARM AUTO DISC

: ON OFF

ALARM AUTO DISC TIMER :

060S

ALARM DIALING TIME TABLE;

TABLE

DAY

TIME

1

MOH-SUH

00:00-00:00

2

MON-FRl

08:30-17:00

3

FRI-MON

17:00-08:00

ENT:DAY

INC.

DEL;CLR

T4.Η>:MOVE ESC:PRV

Move the cursor to ALARM TYPE and select either
LEVEL or EDGE (OPEN CLOSE) with the ^ or ► but­

ton. The default setting is EDGE (CLOSE).

43