Terminate current com. then accept: the, Alarm operation – Panasonic WV-CU20 User Manual

Page 62

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

A dialog saying “RECEIVE A CALL?" may appear on the
Control site monitor while the site is in communication with
a Remote site. This indicates that a new access is made by
another Remote site. The unit processes according to the

selection below.

Alarm Operation

MRSCEIVE A CALL?

IP ADDRESS:

HO.002 Trane,02

ACCEPT

REJECT

HOLD.COHTIHUE CURRENT СОИ.
TERMINATE CURRENT COM.THEN ACCEPT

TI^:MOVE ENT:EXEC

1, Move the cursor to one of the four options below with

the A or ▼ button, then press the ENTER.

ACCEPT: The unit accepts the new access and holds

the current communication.

REJECT: The unit rejects the new access.
HOLD, CONTINUE CURRENT COM.: The unit holds

the new access until the current communication is
terminated.

TERMINATE CURRENT COM. THEN ACCEPT: The

unit terminates the current communication and

accepts the new access.

2. On-hold process

2-1 Press the SWITCH SITE (#3 of the one-touch dial)

button to display the on-hold list. The list shows
suspended callers (transmitter) with registered site
name or IP address respectively.

2-2 Move the cursor to a number you wish to communi­

cate with, then press the ENTER. Communication

will start,

■SWITCH SITES?

N0.001

Trans.01

N0.002

Trans.02

192.168.0.20

tl;MOVE BNT:EXEC ESC:CLEAR

3. Hold down the DIAL button for 2 seconds to terminate

calls. The listed calls will be canceled and a message

"LINE TERMINATED" appears.

Note: When the call is terminated by the Remote site’s

operation, "TERMINAL LEFT" appears on the
Control site monitor,

When a connected (alarm) sensor is activated on the

Remote site, the transmitter calls the Control sites to let

them check the alarm images. Alarm setups are made on
the Remote site in the menus 460 through 465,

When the Control site receives an alarm call, the ALARM

DIAL window appears.

1, Press the ALM ACK button. The camera images asso­

ciated with the sensor is displayed on the Control site
monitor.

2, To escape from the alarm display follow any one below

as the case may be.

• When AUTO DISC (automatic disconnection) is set

to OFF in the 461 ALARM SETUP menu, press the
ALM ACK button.

• When AUTO DISC is set to ON, the alarm display

ends as the preset timer elapses. You can press
the ALM ACK button before the preset timer elaps­
es.

62

Advertising