SERIAL PORT SETUP

On the ADMINISTRATOR SETUP PAGE, dick the SERIAL PORT button to display the SERIAL PORT SETUP window

Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters

Make certain that the DIP switch #4 on the rear of the transmitter is set to OFF when the RS-485 port is used, or to ON when the
RS-232C port

IS

used

86

® TYPE

Specify a peripheral device that communicates with the
transmitter through the serial port Click the ▼ button

repeatedly to scroll down the options shown below

The default setting is PS*Data

The following options are available when DIP switch #4 is

set to OFF (RS-485 ) on the rear of the WJ-NT204

WJ-SX550A/B Matrix Switcher System
WJ-FS616 Video Multiplexer
PS Data Products capable of Panasonic Security Data

protocol

Serial Through Data is transmitted through the DATA

port using comthr html

The following options are available when DIP switch #4 is

set to ON (RS-232C ) on the rear of the WJ-NT204

WJ-SX550A/B: Matrix Switcher System
WJ-SX850 System 850 Matrix Switcher
WJ-DR200 Digital Disc Recorder

Serial Through Data is transmitted through the DATA

port using comthr html

© BAUD RATE

Set the rate to 4 800, 9 600 or 19 200 bps The default
setting IS 9 600 bps

(D

DATA BIT

Set the data bit to 7 or 8 bits The default is 8 bits

® STOP BIT

Set the stop bit to 1 or 2 bits The default is 1 bit

® PARITY

Set the parity check to NONE, ODD or EVEN The
default setting is NONE

® WAIT TIME

Set the wait time with the ▼ button The default setting

® UNIT ADDRESS

Set an address number within 002 through 999 when

TYPE

IS

set to PS’Data The default setting is 002

Notes Special caution should be used for setting unit

address when the System Controller WV-CU360 is
installed in the system

• The transmitter WJ-NT204 will be set to address

"1” automatically, when no receiver \A/J-NT204 is

connected to the transmitter except the PC The
WV-CU360 connected to the transmitter should be
set to other than "1"

The transmitter WJ-NT204 will be set to the

address by this operation, when a receiver \A/J-

NT204 IS connected The Control site WV-CU360

connected to the receiver should be set to “V’
while the Remote site WV-CU360 be set to other
than "1" and " transmitter’s address”

® GROUP ADDRESS

Set an address within OOA through 002 The default
setting IS OOA

@ PS'Data Unit Address SETUP

Is linked to the PS Data Unit Address SETUP page

® WJ-DR200 SETUP

Set the CONTROL PRIORITY from among three

options The default setting is AUTOMATICALLY

CHANGE OVER

(Q) WJ-SX550A/B and WJ-SX650 MATRIX SWITCHER

SETUP
Clicking on this line will open the WJ-SX550A/B and
WJ-SX850 MATRIX SWITCHER setup window