D alarm type, Alarm log clear – Panasonic WV-CU20 User Manual

Page 85

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

(D ALARM TYPE

This setting specifies the sensor (alarm) input reception

whether to accept or ignore depending on the signal

forms, and applies to all 8 inputs on the rear of the
transmitter. The default setting is EDGE (CLOSE).

LEVEL: The transmitter enters the alarm mode when

the input retains active (when low) for more than 1
second,

EDGE (OPEN): The transmitter enters the alarm mode

when the input changes from close to open.

EDGE (CLOSE): The transmitter enters the alarm mode

when the input changes from open to close.

Note: The alarm log may record redundant event when

this setting is changed from one to another.

ALARM PORT Enable/Disable SETUP page
Clicking this lihe opens the setup page.

The sensor inputs connected to the rear of the transmit­
ter unit can be enabled or disabled with this setup. EXT
can be set only for the port #8. This setup is applied
only to the transmitter unit. The default setting is

ENABLE for all ports.

ENABLE: The unit accepts the sensor input.
DISABLE: The unit ignores the sensor input.
EXT: The highest priority is given to #8 port that the

unit ignores inputs to other ports when #8 port is
activated.

© ALARM LOG CLEAR

Click this button to clear the alarm log.

85