KEYENCE LK-CC100/DN100 User Manual

Page 11

Advertising
background image

1-5

1

1 Before Use

Connector

Terminal block

3

1

4

1.1

Disables control input, tolerance comparison and readout of
measurement values for OUT07 and higher.

4

2

1

2.0

Disables control input or tolerance comparison for any OUT,
and disables readout of measurement values for OUT3 and
higher.

5

2

2

2.0

Disables control input or tolerance comparison for OUT05
and on, and disables readout of measurement values for
OUT07 and higher.

6

2

3

2.0

Disables control input or tolerance comparison for OUT09
and on, and disables readout of measurement values for
OUT11 and higher.

7

2

4

2.0

Unused.

8

4

1

2.0

Disables control input or tolerance comparison for OUT03
and on, and disables readout of measurement values for
OUT07 and higher.

9

4

2

2.0

Disables control input and tolerance comparison for OUT11
and higher.

A

4

3

2.0

Unused.

B

4

4

-

Cannot be used due to stress placed on network.

C

8

1

2.0

Disables control input and tolerance comparison for OUT07
and higher.

D

8

2

2.0

Unused.

E

8

3

-

Cannot be used due to stress placed on network.

F

8

4

-

Cannot be used due to stress placed on network.

Terminal name

Function

FG

Functional ground terminal.
Ground to a ground resistance of 100 ohms or less.

SLD

Shield.
Connect shield wire from the dedicated CC-Link cable supporting Ver. 1.10
(OP-79426, OP-79427, etc.).

DG

Communication ground

DB

Communication signal Low

DA

Communication signal High

Switch setting

Multiple

Station

Version

Remark