KEYENCE LK-CC100/DN100 User Manual

Page 24

Advertising
background image

2-10

2

2 Connecting to CC-Link

• n: varies according to the station number of the LK-CC100.
• m (1 to 12): corresponds to the OUT number. m = 1 for OUT01, m = 2 for OUT02, etc.

Read
control
buffer

RY (n+16*m+3)

OUTm_TIM_ON_REQ

• Requests timing ON to OUTm at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+16*m+4)

System reserved

RY (n+16*m+5)

OUTm_TIM_OFF_REQ

• Requests timing OFF to OUTm at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+16*m+6)

System reserved

RY (n+16*m+7)

System reserved

RY (n+16*m+8)

OUTm_ZERO_ON_REQ

• Requests zero ON to OUTm at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+16*m+9)

System reserved

RY (n+16*m+10) OUTm_ZERO_OFF_REQ • Requests zero OFF to OUTm at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+16*m+11)

System reserved

RY (n+16*m+12)

System reserved

RY (n+16*m+13) OUTm_RESET_REQ

• Requests reset to OUTm at the rising

edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+16*m+14)

System reserved

RY (n+16*m+15)

System reserved

RY (n+16*13+0)

System reserved

..

.

System reserved

LK-
CC100

Signal
direction

CC-Link master station

RY
(Remote outputs)

Signal name

Explanation