Changing the CC-Link Communication
Unit Settings

This section explains the principle and operation of the CC-Link communication unit (LK-

CC100).

This manual describes only those functions and settings of the CC-Link master device necessary for
communicating with the LK-CC100. Refer to the manual supplied with the master device for details on
functions and settings between the CC-Link master device and a PLC.

Field network connection specifications

Master settings

To connect the LK-CC100 to the CC-Link master, it is necessary to configure the slave

attribute and memory allocation settings.

Slave attributes

Register the LK-CC100 to the CC-Link master unit as a remote device station.

You can also set this by importing a CSP file into the software for the master unit (ladder

programming software, CC-Link setting software).

Memory allocation settings

In order to exchange data between the LK-CC100 and CC-Link master unit, the memory

allocation must be set using the software for the master unit (ladder programming

software, CC-Link setting software).

• The RX, RY, RWw, and RWr communicated over the CC-Link is stored in the master unit's buffer

memory.

• When multiple slaves are being used, the memory is allocated automatically for each slave

according to the specified starting address. You can view the memory allocation information for
each slave in the CC-Link setting software.

• CSP files can be downloaded from the KEYENCE website.

http://www.keyence.co.jp/

NOTE