KEYENCE LK-CC100/DN100 User Manual

Page 23

Advertising
background image

2-9

2

2 Connecting to CC-Link

RY (Remote outputs)

RY (remote outputs) are control signals sent from the CC-Link master station to the LK-CC100.

LK-
CC100

Signal
direction

CC-Link master station

RY
(Remote outputs)

Signal name

Explanation

Read
control
buffer

RY (n+0)

CHG_PRG_REQ

• Requests to change to the program

number stored in SET_PRG_NUM at
the rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+1)

System reserved

RY (n+2)

SYNC_TIM_ON_REQ

• Requests synchronized timing ON at

the rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+3)

System reserved

RY (n+4)

SYNC_TIM_OFF_REQ

• Requests synchronized timing OFF at

the rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+5)

System reserved

RY (n+6)

SYNC_ZERO_ON_REQ

• Requests synchronized zero ON at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+7)

System reserved

RY (n+8)

SYNC_ZERO_OFF_REQ

• Requests synchronized zero OFF at

the rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+9)

System reserved

RY (n+10)

SYNC_RESET_REQ

• Requests synchronized reset at the

rising edge from OFF (0)

 ON (1).

• Ends the request at the falling edge

from ON (1)

 OFF (0).

RY (n+11)

System reserved

RY (n+12)

System reserved

RY (n+13)

System reserved

RY (n+14)

System reserved

RY (n+15)

System reserved

RY (n+16*m+0)

System reserved

RY (n+16*m+1)

System reserved

RY (n+16*m+2)

System reserved