KEYENCE LK-CC100/DN100 User Manual

Page 50

Advertising
background image

3-14

3

3 Connecting to DeviceNet

Input data buffer

The input data buffer refers to the area where the statuses of LK-DN100 are stored.

• A word is 16 bits.
• m (1 to 12): corresponds to the OUT number. m = 1 for OUT01, m = 2 for OUT02, etc.

LK-
DN100

Signal
direction

DeviceNet master node

Offset

Signal name

Explanation

Write
data
buffer

Word (14)

CUR_PRG_NUM

Stores the current program selection
number from 0 to 7.

Word (15)

SYSTEM_ERR_NO

Stores the system error number when the
SYSTEM_ERR_FLAG turned ON (1).

Word (16)

COUNTER_LO

Stores the unsigned 32-bit counter value.

• Increments the count each time a

measurement value is acquired from the
controller.

• Count does not increment if

READY_FLAG is OFF (0).

Word (17)

COUNTER_HI

Word
(2*(m+8)+0)

OUTm_LO

Stores the measurement value for OUTm.
* This register assumes the following values
in these instances:

Comparator standby = 0xFFF00000
Alarm = 0x000FFFFF
- Range over = 0xFFF00001
+ Range over = 0x000FFFFE

Word
(2*(m+8)+1)

OUTm_HI