Removing the pole, Procedure a, Caution – A&D Weighing HW-1200KGV3 User Manual

Page 16

Advertising
background image

Page 14

HV-G/HW-G Series

5. Installing the Scale

5.3. Removing

the

Pole

Caution

Remove the AC plug from the receptacle before removing the pole (type V).

Remove the AC adapter and batteries before removing the pole (type L).

When removing the load cell cable, do not pull on the load cell cable

connector forcibly and do not pull on the wires of the cable.

Do not bend the cable forcibly. Use care so that the load cell cable does not
touch the pan inside the base unit.

Avoid dust, static electricity and high humidity (or condensation) because the
inside of the display unit is sensitive.

The pole removing procedure depends on the scale model. Refer to the table below.

Models

Refer to

HV-15KGL/HV-15KGV/HV-60KGL/HV-60KGV/HV-200KGL/HV-200KGV/HW-10KGL
HW-10KGV/HW-60KGL/HW-60KGV/HW-100KGL/HW-100KGV/HW-200KGL/HW-200KGV

Procedure A

HW-300KGL4/HW-300KGV4/HW-600KGL4/HW-600KGV4/HW-600KGL3/HW-600KGV3
HW-1200KGL3/HW-1200KGV3

Procedure B

5.3.1. Procedure A

Step 1 Turn the scale off.

Remove the AC plug from the receptacle (type V).

Remove the AC adapter and batteries (type L).

Step 2 Open the rear cover of the display unit.

Disconnect the load cell cable connector gently

(perpendicularly and do not pull toward you).

Step 3 Remove the two 4 mm screws, which are used

to attach the display unit to the pole.

Step 4 Remove the ferrite core and the cable clamp

from the load cell cable.

Step 5

(HV-60KGL/HV-60KGV/HW-60KGL/HW-60KGV/HV-
200KGL/HV-200KGV/ /HW-100KGL/HW-100KGV
HW-200KGL/HW-200KGV only)

Remove the 3 mm screws from the bottom
cover of the bracket.

Step 6 Carefully remove the load cell cable from the

pole and the bracket while using care not to pull
on the connector forcibly.

Step 7 Arrange the cable so that it does not touch the

pan in the base unit. The untied cable is
approximately 2 m. The optional extension load
cell cable (OP-02) is 5 m long.

Step 8 Remove the bracket from the base unit. An

Allen wrench is required.

HV-15KGL/HV-15KGV
HV-60KGL/HV-60KGV
HW-10KGL/HW-10KGV
HW-60KGL/HW-60KGV

HV-200KGL/HV-200KGV
HW-100KGL/HW-100KGV
HW-200KGL/HW-200KGV

5 mm Allen wrench

6 mm Allen wrench

Bracket

Allen screw

Allen wrench

Bracket (Middle and large sized models)

Pole

Bottom cover

3 mm screws

Load cell cable

Rear cover

Cable clamp

Ferrite core

Wind up 2 times

4 mm screw

Connector