Page 26

HV-G/HW-G Series

7. Basic Operation

7.3. Weighing Range for the HV-G Series

This is the function to select a weighing range for the HV-G series.

The mass value is displayed within a selected range.

Select automatic range (f2 0) or manual range (f2 1) in the function table.

Operation and Performance

Function table

Description

A

f2 0

Automatic range

The weighing range changes automatically, if the weight value

proceeds from narrow range to wide range when articles are
placed on the pan.

When there is nothing on the pan and the zero point mark is

displayed, the weighing range changes to the minimum range
automatically.

When the zero point mark is not displayed due to net display

or zero error, press the

ZERO

key, with nothing on the pan, to

change to the minimum range.

A
A
A
A
A
A
A
A
A

f2 1

Manual range

Press

the

RANGE

key to expand the range.

Press

the

RANGE

key to change to the minimum range, when

there is nothing on the pan and the zero point mark is
displayed.

When the zero point mark is not displayed due to net display

or zero error, press the

ZERO

key and the

RANGE

key, with

nothing on the pan, to change to the minimum range.

A
A
A
A
A
A
A
A

Weighing Range

Models Weighing

range

A

HV-15KGV, HV-15KGL

3 kg,

6 kg ,

15 kg

A

HV-60KGV, HV-60KGL

15 kg,

30 kg,

60 kg

A

HV-200KGV, HV-200KGL

60 kg,

150 kg,

220 kg

A