A&D Weighing HW-1200KGV3 User Manual

Page 56

Advertising
background image

Page 54

HV-G/HW-G Series

15. The Function Table

Item

Display Description

f8 4

When the display is a stable value and not nearly-zero, the scale
accumulates the data automatically. The next accumulation can
be performed after the display becomes nearly-zero.
Use

Recording the number and mass of articles removed
from the pan. (Place the articles on the pan. Press the

TARE

key at each removal.)

A
A
A
A
A
A

Accumulation
function

f8 5

At each end of the full/dribble batch function, the scale
accumulates the data automatically.
Use

Packaging articles like a powder, it is used for recording
the bag number and total mass.

A
A
A
A

Selects the printing condition. Option OP-06 for type V is
required.

f9 0 # No

print.

f9 1

Press the

PRINT

key to output the data.

f9 2

Auto-print +
When the display becomes a positive stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero or negative value.





f9 3

Auto-print +/-
When the display becomes a stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero.




f9 4

At each end of full/dribble batch function, the data is output.

Print mode

f9 5

When the accumulation function is used, the data is output.

Selects the details of the full/dribble batch function (f6 9)

f10 0 #

When the

F

key is pressed after final value is reached, the

current process is finished.

A
A

f10 1

When the stability mark is displayed after final value is reached,
the current process is finished automatically.

A
A

f10 2

When the

SET

key is pressed, the scale automatically tares and

starts the full/dribble batch process. When the

F

key is pressed

after final value is reached, the current process is finished

A
A
A

Full/Dribble
batch
sub-func-ti
on

f10 3

When the

SET

key is pressed, the scale automatically tares and

starts the full/dribble batch process. When the stability mark is
displayed after final value is reached, the current process is
finished.

A
A
A

Select the address for RS-422 / RS-485 for option OP-04

f11 00 #

Address

f11 01

to

f11 99

Use Addresses from 01 to 99 are available. Scales are

assigned unique addresses and are controlled by the
computer.

(RS-232C should be set to "00".)



"#": factory settings. The "nearly-zero" is within ±5 digits from zero point in the unit of kg.

Advertising