Simple batch function – A&D Weighing HW-1200KGV3 User Manual

Page 46

Advertising
background image

Page 44

HV-G/HW-G Series

13. Simple Batch Function

13. Simple Batch Function

This function compares a weight value with the final value, preliminary value and zero

band for the full/dribble batch function. The result is indicated by zero band (LO
indicator), full flow (HI indicator) and dribble flow (OK indicator). Even if the weight
value is increasing or decreasing, this function can compare it.

To use this function, set the parameters of the "Simple batch function (

f6 8

)" in the

function table, final value (HI), preliminary value (OK) and zero band (LO).

Install option OP-03 or OP-04 to use the relay output of the comparison.
Install option OP-03 to use the buzzer output of the comparator.
The settings are stored in the scale even if the power is removed. (Refer to Caution

on the next page.)























Comparison Condition

Gross

Zero band ..............LO is displayed and output.

Final - Preliminary ≦ Net .........................OK is displayed and output.

Final

Net .........................OK, HI are displayed and output.


Parameter List and Word Definition

The "gross" is a total weight value (the tare value is not subtracted).
The "net" is a measurement value with the tare value subtracted from the gross.
The "tare" is an item placed on the pan and its mass is subtracted from the gross.
The "zero band" means the zero detection level.
The "zero point" is the fundamental starting point to weigh anything.

Function table

Description

A

f6 8

Simple batch function

A

Advertising