Rs-232c serial interface – A&D Weighing HW-1200KGV3 User Manual

Page 58

Advertising
background image

Page 56

HV-G/HW-G Series

16. RS-232C Serial Interface

16. RS-232C Serial Interface

Note When the RS-232C serial interface is used, be sure to set the “Address (

f11

) “ to

“(

00

)”.

RS-232C interface has the following two modes.

Stream mode

Outputs data continuously and can be used to print data.

Command mode Controls the scale using commands from a computer.

To use RS-232C interface, set the parameters of the “Baud rate (

f4

)”, “ Output

mode (

f5

)”, “ Format (

f15

)” in the function table.

Optional cables are available as follows:

AX-KO577A-200

RS-232C

cable, D-sub 25 pin, 2 m

AX-KO1786-200

RS-232C cable, D-sub 9 pin, 2 m

Transmission system

EIA RS-232C

Transmission

Asynchronous, bi-directional, half-duplex

Data format

Baud rate

2400, 4800, 9600 bps

Data

7

bits

Parity

1 bit, Even

Start bit

1 bit

Stop bit

1 bit

Code

ASCII

Terminator

CR LF (CR: 0Dh, LF: 0Ah)

Pin

connections

Pin No. Signal name

Direction

Description

A

1 -

A

2 RXD

Input Receive

data

A

3 TXD

Output Transmit

data

A

4 -

A

5 SG

-

Signal

ground

A

6 -

A

7

DSR

Output

Data set ready

A

8 -

-

Circuits








Adaptable connector

DIN 8 pin (TCP0586)

Advertising