A&D Weighing HW-1200KGV3 User Manual

Page 63

Advertising
background image

HV-G/HW-G Series

Page 61

16. RS-232C Serial Interface

Preset tare

Tare value is set and the net is displayed.

The set value is a 5 digit numerical value with a polarity sign and does not contain a
decimal point.
Template PT,

[parameter]

Command

Reply

Net is displayed and the net mark is displayed.


Upper limit value

The upper limit value is stored. The set value is a 5 digit numerical value with a
polarity sign and does not contain a decimal point.

Template HI,

[parameter]

Command

Reply

The upper limit value is stored.

Caution

The upper limit value must be greater than the lower limit value.

Lower limit value

The lower limit value is stored. The set value is a 5 digit numerical value with a polarity
sign and does not contain a decimal point.

Template LO,

[parameter]

Command

Reply

The lower limit value is stored.

Caution

The lower limit value must be less than the upper limit value.


Accumulation data output

Accumulated data is output.

Template A
Command

Reply


Accumulation count output

Number of accumulations is output.

Template N
Command

Reply


Reset of Accumulation data and Accumulation count

Accumulated data and number of accumulations are set to zero.

Template CA
Command

Reply

Data and number of accumulations become zero.