9. Percentage Mode

9. Percentage Mode

The percentage mode is the function to display a mass value in the unit of "%".

To use this function , store a 100% mass value in advance.

The 100% mass value is stored in the scale even if the power is removed.

9.1. Storing a 100% Mass

Step 1 Press the

MODE

key to display the unit %.




Step 2 Press the

SET

key to enter the mode that stores a

100% mass.




Step 3 With nothing on the pan, press the

ZERO

key to

display zero.





Step 4 Place the 100% mass on the pan gently.

Wait for the stability mark to be displayed. Press the

ENTER

key to store. The percentage is displayed.

Caution

When the sample is too light and it is not possible
to calculate a 100% mass, the scale displays

lo

.

and returns to step 3.

Pressing

the

ENTER

key, after

lo

is displayed,

displays the next unit.


Step 5 Remove the mass from the pan.


Percentage mode

100% mass

STABLE

Zeroing value

Pan

STABLE

STABLE

Note

The pan shape depends

on the scale model.

Advertising