25 empty alarm setting, Fluid empty alarm setting, Changing the empty alarm setting – Toshiba LF600F User Manual

Page 101: Toshiba

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TOSHIBA

,6,F,8,A0,8,6,9,

8.2.25 Empty Alarm Setting

You can set the empty alarm to detect an empty condition in the pipe. If the fluid is run out when
the empty alarm is set to "On", EMPTY ALARM is displayed.

# Fluid empty alarm setting

Selection item

Contents

OFF

Fluid empty alarm disabled

NORMAL

Fluid empty alarm enabled Sensitivity level Low

SENSITIVE

Fluid empty alarm enabled Sensitivity level Middle

SENSITIVE-H

Fluid empty alarm enabled Sensitivity level High

* When setting the fluid empty alarm to be "enabled", usually set NORMAL (sensitivity level

Low). Set a sensitivity level of SENSITIVE or SENSITIVE-H only when it is difflcult to
detect an empty condition due to the status of the operating fluid and the piping.

Changing the empty alarm setting

Key operation

Display example

Description

K:

Select "EMPTY ALM" in the configuration item selection

MEAS MODE

->EMPTYALM

SELF CHECK

ALM PRESET

[SEL] [ENT]

screen.

STEP1

K1:

The current setting value (OFF in this example) is

EMPTY ALM

OFF

displayed.

[ENT]

Then press the [ENT] key.

[EXT] [ENT]

* Pressing the [EXT] key returns you to the menu screen.

STEP2

K1:

The switch name display at the bottom changes (three

EMPTY ALM

Bigg

keys [UP], [DOWN] and [SET]).

At the same time, the cursor appears.

[ENT]

(The digit on which the cursor is positioned is

fU PI fDWNl iSETl

reverse-displayed.)

STEP3

K1:

EMPTY ALM

Change the selection item using the [L)P]/[DWN] key.

^H

sensetive

-

h

^H

When you have selected the desired item, press the [SET]

[UP]/[DWN]

fU PI [DWN] fSETl

key.

STEP4

K1:

When you press the [SET] key, the selected item is set

EMPTY ALM

temporarily and a message confirming you whether the

SENSITIVE-H

setting is OK is displayed.

[SET]

/

OK? *

IN 01 fSETl

If OK, press the [SET] key. If you want to redo the setting.

press the [NO] key.

STEP5-1

K1:

Pressing the [NO] key when you are asked "OK?" causes

EMPTY ALM

PWl

the setting value to return to the previous value and

[NO]

BIM

fU PI [DWN] fSETl

enables you to redo the setting.

STEP5-2(=END)

K1:

Pressing the [SET] key when you are asked "OK?" causes

EMPTY ALM

the setting to be determined.

SENSITIVE-H

Then press the [EXT] key. You return to the menu screen.

[SET]

Pressing the [ENT] key enables you to restart setting

fEXTl fENTl

operation from a state of SENSITIVE-H.

-

100

-

Advertising
This manual is related to the following products: