Using the digital input signal

Remote operations for the totalizer and pulse output can be conducted using the digital input signal.

The following functions in the table can be performed. See 0 “Digital I/O” to select these functions.

Operation with the digital input signal (Initial setting: H level in control level)

Digital

input

(DI)

Functions

DI voltage level

Totalizer and pulse output

Totalizer

Start/Stop

L level

Stops the totalizer and the pulse output.

H level

Start the totalizer and the pulse output.

Totalizer

Reset/Start

H level

Stops and clears (resets) the totalizer.

L level

Start the totalizer and the pulse output.

You can reverse the digital input detective level. For detail, see 8.2.12 “Digital Input Detective
Level.”

* Select H level (1:H LEVEL) :

The operation with the digital input signal is same as the

standard converter shown in the above table.

* Select L level (0:L LEVEL) ; The operation with the digital input signal is same as the

standard converter shown in the below table.

Operation with the digital input signal (Control signal level: L level in control level)

Digital input (DI)
Functions

DI voltage level

Totalizer and pulse output

Totalizer

Start/Stop

L level

Start the totalizer and the pulse output.

H level

Stops the totalizer and the pulse output.

Totalizer
Reset/Start

H level

Start the totalizer and the pulse output.

L level

Stops and clears (resets) the totalizer.

-

119

-