TOSHIBA

6|F,8iA0i8,6|9|

8.2.9 Custom Coefficient Setting

Set a coefficient for the custom value displayed when you have selected CUSTOM at display setting.

Displayed value at CUSTOM setting = measured value in m^/min unit x custom coefficient

Shown below is an example of changing the custom coefficient value from 1.00 to 2.25.

Key operation

Display example

Description

B;

Select "CUSTOM DATA" in the configuration item

MEAS MODE

MAIN DSP

SUB DSP

^CUSTOM DATA

CUSTOM UNIT

LCD ADJUST

SW POSITION

iSELl fENTl

selection screen.

STEP1

B3:

The currently set custom coefficient (1.00000 in this

CUSTOM DATA

1.00000

example) is displayed.

[ENT]

Then press the [ENT] key.

[EXT] [ENT]

* Pressing the [EXT] key returns you to the menu

screen.

STEP2

B3:

The switch name display at the bottom changes

CUSTOM DATA

(three keys [UP], [SEL] and [SET])

H.00000

At the same time, the cursor appears.

[ENT]

[U P] [SEL] [SETl

(The digit on which the cursor is positioned is

reverse-displayed.)

STEPS

B3:

Use the [SEL] key to move the cursor to the desired

CUSTOM DATA

digit and press the [UP] key to change the numeric

2.2@000

value.

[SEL]<^[UP]

Repeat this operation to change the setting value to

2.25.

[U P] [SEL] [SET]

When the value changes to the desired value, press

the [SET] key to set the custom coefficient

temporarily.

STEP4

B3:

Pressing the [SET] key displays a message asking

CUSTOM DATA

you to confirm whether the setting is OK.

2.25000

If OK, press the [SET] key. If you need to redo the

[SET]

OK?

^

(N01 [SETl

setting, press the [NO] key.

STEP5-1

B3:

Pressing the [No] key when you are asked "OK?"

CUSTOM DATA

causes the custom coefficient to return to the

[NO]

D-00000

[U PI [SELl [SETl

previous value and enables you to redo the setting.

STEP5-2(=END)

B3:

Pressing the [SET] key when you are asked "OK?"

CUSTOM DATA

causes the setting value to be determined.

2.25000

Then if you press the [EXT] key, you return to the

[SET]

menu screen.

If you press the [ENT] key, you can restart custom

[EXTl [ENTl

coefficient change operation from a state of 2.25.

* The custom coefficient setting precision is 5 digits. Therefore, the input value changes as

follows depending on the setting value:

Example) Input value, ”85713038" —^ After the setting is confirmed, "85713040”

-