(3) The following is an example for one-shot pulse output.

200

100

ON

OFF

For it takes the time set pulse width

from the output goes OFF

Input/Output signal time chart

* Preset output goes ON when the count value exceeds the preset value of 100 and the preset

output goes OFF when its width reaches the set pulse width.
When the preset value exceeds 100, the preset value is changed to 200 (adding the preset count of

100

to the current preset value of

100

).

Then, the preset output goes ON when the count value exceeds the preset value of 200, and
the preset output goes OFF when its width reaches the set pulse width.
When the preset value exceeds 200, the preset value is changed to 300 (adding the preset
count of

100

to the current preset value of

200

).

Note:

When the one-shot pulse output function is selected, if its pulse width is large compared
with the update period of the preset value. The output stays ON. To make sure to
output as one-shot pulse, set the preset value reach interval to be

2

signals or more of

the pulse width setting value.

Preset Pulse

Width

The Interval of that

Totalizer reaches the

Preset Point

Example) Count rate:0.011

Flow verosity:10 l/s

Totalizer count up rate:1ms/COUNT

50ms

More than 100ms

Preset Count: more than 100

500ms

More than 1000ms

Preset Count: more than 1000