TOSHIBA

i6,F,8,A0,8,6,9,

Appendix 3

Electromagnetic Compatibility and Low Voltage Safety

LF600F and LF602F

electromagnetic flowmeter converter has been confirmed to comply with the

requirements of the EMC directive 89/336/EEC and the low voltage directive 93/68/EEC.

EMC directive

This device has been tested in a typical configuration in accordance with the following standards in an

industrial environment.

Generic emission standard

Conducted RF emissions

Radiated RF emissions

Generic immunity standard

Conducted RF immunity

Radiated RF immunity

Electrostatic discharge

Fast transient burst

EN50081-2

EN55011

EN55011

EN50082-2

ENV50141

ENY50140/ENV50204

EN61000-4-2

EN61000-4-4

The above EMC tests have been carried out with the flowmeter installed properly in accordance with

this instruction manual. However, there is no guarantee that interference will not occur in a particular

installation.

To reduce interference to or from other equipment, please check the following installation points.

(1) Use shielded cables for all I/O cables. When the flowmeter is the separated type, the signal cable

and excitation cable for the connection between the detector and the converter are supplied by
Toshiba. To improve immunity, pass each cable through a thick steel conduit tube.

(2) If this device is installed in an area where RFI exists, deviation of the current output signal may

be caused. In this case, ferrite cores will be required on each I/O cable. Please contact Toshiba or

the agency if required.

(3) This device is designed to be used in an industrial environment and may cause reception

interference to radio, television or wireless communications. In this case, relocate the receiving

antenna.

(4) The use of a transceiver or wireless equipment near this device may cause interference to the

accurate measurement. If deviation of the output signal appears during use of a radio, increase
the distance between the converter or the signal cable and the antenna.

Low voltage directive

Low voltage standards

EN61010-1

Environmental conditions:

Installation category

II

Pollution degree

2

Altitude

Up to 2000 m

Other conditions are specified in Chapter 15, “Specifications.”

-